Product Cover Timer Relay, DROK Time Delay Relay DC 5V 12V 24V Delay Controller Board Delay-off Cycle Timer 0.01s-9999mins Trigger Delay Switching Relay Module with LCD Display Support Micro USB 5V Power Supply

Timer Relay, DROK Time Delay Relay DC 5V 12V 24V Delay Controller Board Delay-off Cycle Timer 0.01s-9999mins Trigger Delay Switching Relay Module with LCD Display Support Micro USB 5V Power Supply

$13.89
$13.89
For Bulk orders
Quantity


  • Features
  • Description
  • Similar Items
DROK timer relay operating voltage range is DC 6-30V, support micro USB 5.0 V power supply; support high level trigger 3.0v-34v and low level trigger 0v-0.2v; timing range is 0.01s~9999mins, can be continuously adjustable.

LCD Display: the time delay relay module is designed with LCD display, can clearly and directly show the current mode and parameters.

Sleep Mode: without any operation within 5 minutes, the LCD backlight of the relay board will close automatically. Any button can wake up.

Independent Parameters: OP/CL/LOP parameters can be modified and saved, and they are individual.

Auto Save: All setting parameters are automatically saved by power-fail.

Binding:

Misc.

Brand:

DROK

EAN:


Label:

DROK

Manufacturer:

DROK

Model:

200350

Size:


Warranty:


Product Parameters:
Working voltage: DC 6V~30V, support micro USB 5.0 V power supply
Working current: 50mA.
Static Current: 15mA
Max. Output load: DC 30V 5A and AC 220V 5A.
Trigger signal source: High level trigger (3.0V~24.0V), low level trigger (0.0V ~0.2V), switching value control (Potential free contact)
Service life: more than 100,000 times
Working temperature: -40-85°C

Additional Functions:
a)Automatically hibernation function/ Low power function: In the running interface, long press STOP to open or close automatically sleep function. (L-P selects ON to start the hibernation function, and OFF turns off the hibernation function);
b)Relay function selection: In the operation interface, shortly press STOP, the relay function is started or closed, 'ON' meets the conduction condition and the relay normally turns on, 'OFF' meets the conduction condition and the relay does not turn on; In the 'OFF' state, the system flashes 'OUT'.
c)Parameters view: In the operation interface, short press SET to display the current parameter setting in the system, without affecting the system normal operation.
d)Display content switching: In the P-5 P-6 mode, switch display content (runtime/cycle times) by pressing DOWN.

Package Includes:
1* 12V Timer Relay